ㆍNo. 2018-1 for noise and vibration measurement agency
Noise is a sound that interferes with life emotions or functions, and is a strong sound produced by using machinery, tools, facilities, or other objects generated from factories,
construction sites, roads, and railroads. . These are harmful regardless of the type or quality of snow. Along with urbanization, the main life is exposed to a lot of living noise,
and the comfort of the dwelling is impaired. Therefore, when a house is constructed from the beginning, if the noise level at the construction site is 65 dB or more, it must be
separated from the noise generation boundary by a horizontal distance of 50 m or more, or soundproofing facilities such as sound-proof walls and forest belts must be
installed so that the noise level is less than 65 dB. In addition, living noise such as noise from loudspeakers and noise from factories and workplaces is subject to regulation.
The basis is the regulations on housing construction standards, etc.
Living noise regulation standard (Article 20 Paragraph 3) [Unit: dB(A)]
Target area |
Noise source |
Morning, Evening
(05:00 ~ 07:00, 18:00 ~ 22:00) |
Daytime
(07:00 ~ 18:00) |
Night
(22:00 ~ 05:00) |
A. Schools, general hospitals,
and public libraries in residential areas,
green areas management areas,
mid-settlement districts,
residential development promotion districts,
tourism and recreation development promotion districts,
natural environment conservation areas, and other areas |
Loud speaker |
Outdoor installation |
60 or less |
65 or less |
60 or less |
When noise comes from indoors to outdoors |
less than 50 |
55 or less |
45 or less |
Factory |
less than 50 |
55 or less |
45 or less |
Place of business |
Same building |
45 or less |
less than 50 |
40 or less |
etc |
less than 50 |
55 or less |
45 or less |
Construction site |
30 or less |
65 or less |
less than 50 |
B. Other areas |
loud speaker |
Outdoor installation |
65 or less |
70 or less |
60 or less |
When noise comes from indoors to outdoors |
60 or less |
65 or less |
55 or less |
Factory |
60 or less |
65 or less |
55 or less |
Place of business |
Same building |
less than 50 |
55 or less |
45 or less |
etc |
60 or less |
65 or less |
55 or less |
Construction site |
65 or less |
70 or less |
less than 50 |
Living vibration regulation standard[Unit: dB(A)]
Target area |
Daytime
(06:00 ~ 22:00) |
Night
(22:00 ~ 06:00) |
A. schools, general hospitals,
and public libraries in residential areas,
green areasmanagement areas,
mid-settlement districts,
residential development promotion districts,
tourism and recreation development promotion districts,
natural environment conservation areas,
and other areas |
65 or less |
60 or less |
B. Other areas |
70 or less |
65 or less |