NoiseㆍSound

SIDACOUSTIC Co., Ltd. a company that pursues only the best

Noise and Vibration Measurement Agency

ㆍNo. 2018-1 for noise and vibration measurement agency

Noise is a sound that interferes with life emotions or functions, and is a strong sound produced by using machinery, tools, facilities, or other objects generated from factories,
construction sites, roads, and railroads. . These are harmful regardless of the type or quality of snow. Along with urbanization, the main life is exposed to a lot of living noise,
and the comfort of the dwelling is impaired. Therefore, when a house is constructed from the beginning, if the noise level at the construction site is 65 dB or more, it must be
separated from the noise generation boundary by a horizontal distance of 50 m or more, or soundproofing facilities such as sound-proof walls and forest belts must be
installed so that the noise level is less than 65 dB. In addition, living noise such as noise from loudspeakers and noise from factories and workplaces is subject to regulation.
The basis is the regulations on housing construction standards, etc.

Living noise regulation standard (Article 20 Paragraph 3) [Unit: dB(A)]

Target area Noise source Morning, Evening
(05:00 ~ 07:00, 18:00 ~ 22:00)
Daytime
(07:00 ~ 18:00)
Night
(22:00 ~ 05:00)
A. Schools, general hospitals,
and public libraries in residential areas,
green areas management areas,
mid-settlement districts,
residential development promotion districts,
tourism and recreation development promotion districts,
natural environment conservation areas,
and other areas
Loud speaker Outdoor installation 60 or less 65 or less 60 or less
When noise comes from
indoors to outdoors
less than 50 55 or less 45 or less
Factory less than 50 55 or less 45 or less
Place of business Same building 45 or less less than 50 40 or less
etc less than 50 55 or less 45 or less
Construction site 30 or less 65 or less less than 50
B. Other areas loud speaker Outdoor installation 65 or less 70 or less 60 or less
When noise comes from
indoors to outdoors
60 or less 65 or less 55 or less
Factory 60 or less 65 or less 55 or less
Place of business Same building less than 50 55 or less 45 or less
etc 60 or less 65 or less 55 or less
Construction site 65 or less 70 or less less than 50

Living vibration regulation standard[Unit: dB(A)]

Target area Daytime
(06:00 ~ 22:00)
Night
(22:00 ~ 06:00)
A. schools, general hospitals,
and public libraries in residential areas,
green areasmanagement areas,
mid-settlement districts,
residential development promotion districts,
tourism and recreation development promotion districts,
natural environment conservation areas,
and other areas
65 or less 60 or less
B. Other areas 70 or less 65 or less
맨위로